Tag Archives: ICP-MS

A Survey of Material Science and Physical Characterization Techniques and Equipment for Small Molecules – Part I 

Material science and physical characterization are crucial to ensure drug products’ or drug substances’ identities with measurements and analysis. There are many types of techniques and equipment to do this, each with its own features and qualities. In this blog, the first part of a series, we will review the advantages of a range of techniques and equipment. 

We’ll begin with X-Ray Powder Diffraction (XRPD) or XRD analysis. It is a powerful, non-destructive, and rapid technique for analyzing a wide range of materials (1 µm to 100 mm), including metals, polymers, catalysts, plastics, pharmaceuticals, and other materials. It is used for identification, crystal form characterization, and crystalline content in amorphous products.  

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) is useful for the detection of elemental content and elemental impurities. ICP-MS is also 

efficient as it is a multi-element technique. Ions are directly detected by an MS detector rather than by emission of light, as in the case of ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy). The ions are separated by a Quadrupole based on the mass-to-charge ratio. The best detection limits are available for most of the elements in ICP-MS as the number of ions produced is high, and although some spectral interference is seen, these are defined and limited.   

Dynamic Vapor Sorption (DVS) is a gravimetric technique used to measure the change in

 mass of a material in response to changes to surrounding conditions such as temperature or humidity. DVS is primarily used with water vapor but can be applied to other organic solvents as well for the physicochemical characterization of solids.  Some of the most common uses of DVS include:  

  • To determine the sorption isotherm;   
  • To evaluate the hygroscopicity of an API powder;   
  • To compare the hygroscopicity of different solid-state forms: solvates, polymorphs, salts, amorphicity, and cocrystals;  
  • To determine the deliquescence point of a material;  
  • To quantify and qualify the amorphous content in drug substance or excipient, and 
  • To evaluate the efficacy of packaging materials. 

We will wrap up with Differential Scanning Calorimetry (DSC). It is one of the most used thermoanalytical techniques for determining freezing and melting points and phase transitions. Specifically, it measures the heat flow produced by a sample when it is either heated, cooled, or held isothermally at an unchanging temperature. Crystallization behavior and chemical reactions are some other characteristics that can be measured by this technique. 

Our next entry will conclude with a look at Thermogravimetric Analysis (TGA), Fourier-Transform Infrared Spectroscopy (FTIR), Nuclear Magnetic Resonance (NMR), and, of course, the definitive analytical technique, Mass Spectroscopy (both GCMS and LCMS). 

Resources 

Raw Materials Testing: Trust – and Verify – Your Sources

The CGMP guidance for APIs from the FDA states that raw material specifications should be established and documented. The guide’s key line states, “Quality measures should include a system for testing raw materials, packaging materials, intermediates, and APIs. (19.23)”1 

Medical products, pharmacology, dietary supplements

All raw materials used in producing APIs for clinical trials must be evaluated by testing or received from the supplier with accompanying analysis and subsequently subjected to identity testing. Raw materials and intermediates need to be designated by names and/or specific codes so that any special quality characteristics can be readily identified. Furthermore, written procedures should provide for the identification, documentation, appropriate review, and approval of any changes to raw materials. Additionally, changes to supply sources of critical raw materials should be treated according to the FDA’s established change control guidelines.  

A Range of Tests for Raw Materials Are Available
Some of the categories and tests that can be utilized for raw materials testing include: 

  • Determination of Physical Properties (appearance/description, density, refractive index, pH, water content by Karl Fischer titration (coulometric and volumetric), the color and clarity of the solution, conductivity, optical rotation, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), osmolality, particle counting, particle size distribution (wet and dry), total organic carbon (TOC), and various compendial tests) 
  • Identification (appearance/description, infrared spectroscopy – ATR, salt pellets, and salt plates (for liquids), nuclear magnetic resonance (NMR), liquid chromatography – HPLC and UHPLC, gas chromatography (GC), ion chromatography (IC), mass spectrometry (MS), ultraviolet spectroscopy (UV), X-ray powder diffraction (XRPD), residue on ignition/sulfated ash, ICP-MS and ICP-OES for elemental impurities, and various compendial tests) 
  • Assay and Impurity Testing (standard titration methods, liquid chromatography (both HPLC and UHPLC) detection systems including UV, MS, RI, and CAD (charged aerosol detection), residual solvents testing utilizing gas chromatography systems equipped with FID flame-ionization detection), ECD (electron capture detection), TCD (thermal conductivity detection) and MS, ICP-OES, ICP-MS, and a variety of pharmacopeia methods such as residue on ignition/sulfated ash, heavy metals, etc.) 
  • Pharmacopeia Testing (the ability to qualify and implement monographs and testing chapters from the various pharmacopeias and their standards, including USP (United States Pharmacopoeia), EP (European Pharmacopoeia), BP (British Pharmacopoeia), JP (Japanese Pharmacopoeia), FCC (Food Chemical Codex), and ACS (American Chemical Society, Reagent Standards)) 

Trust – and Verify – Your Raw Materials Testing Solution
The range of testing requirements, procedures, and record-keeping can be daunting. It is crucial to have an experienced, reputable, and thorough laboratory available to ensure that each raw material is released in accordance with regulations. It is also important that the partner you choose to perform these tasks does so in a timely manner, communicating every step of the way. AMPAC Analytical has decades of experience along with the resources to provide all the analytical solutions listed above, combined with a responsive customer service attitude, and a demonstrated history of regulatory audit compliance. We urge that you contact AMPAC Analytical today to learn more about you can trust and verify all your raw materials. 

 References 

  1. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/guidance-industry-q7a-good-manufacturing-practice-guidance-active-pharmaceutical-ingredients#P309_13037